| Required Motion | Rotary indexing, positioning, dosing, valve actuation, airflow control, and light automation | Continuous rotation, point-to-point positioning, or incremental indexing | Use a PM stepper motor when predictable incremental motion and simple open-loop control are required. | List the number of required positions, movement profile, and whether position feedback is needed. |
| Step Angle | 7.5° or 15° per full step | Required angular resolution before microstepping | A smaller step angle provides finer basic positioning. A 7.5° motor provides 48 full steps per revolution, while a 15° motor provides 24. | Calculate full steps per revolution as 360° ÷ step angle and confirm the mechanical resolution requirement. |
| Positioning Resolution | Typical full-step resolution: 24–48 steps/revolution | Target resolution in degrees, millimeters, or repeatable indexed positions | Microstepping can increase command resolution, but actual accuracy and repeatability also depend on load, friction, detent torque, and drive quality. | Test positioning under the real load rather than relying only on the commanded microstep count. |
| Load Torque | Approximately 0.01–0.20 N·m for many compact PM stepper motors | Running torque, acceleration torque, and any static holding requirement | Select a motor whose available torque at the intended speed exceeds the calculated load torque with a practical safety margin. | Include friction, gravity, belt or gear losses, acceleration torque, and unexpected resistance. |
| Torque Margin | Common design target: at least 30% margin; higher for uncertain loads | Required reserve torque above the calculated operating point | A torque margin helps reduce missed steps caused by load variation, resonance, voltage changes, or mechanical wear. | Compare the manufacturer torque-speed curve with the complete motion profile, not only the holding-torque value. |
| Operating Speed | Often most practical below approximately 300–600 rpm | Minimum, normal, and maximum rotational speed | PM stepper torque generally decreases as speed rises. Confirm that sufficient dynamic torque remains at the required speed. | Evaluate pull-in and pull-out performance during starting, stopping, acceleration, and deceleration. |
| Acceleration and Deceleration | Application-dependent; gradual ramping is normally preferred | Start/stop frequency, ramp time, acceleration rate, and movement distance | Use an acceleration ramp when the load has significant inertia or when direct starting could cause stalling or missed steps. | Test the shortest movement and highest acceleration condition, which can be more demanding than steady running. |
| Rated Voltage | Common compact motor ratings: approximately 5–24 V DC | Available supply voltage and driver output voltage | Match the motor winding rating to a compatible current-limiting driver. A higher drive voltage can improve high-speed current rise when the driver is designed for it. | Check winding resistance, inductance, driver voltage limits, and current regulation before operation. |
| Winding Current | Approximately 0.2–2.0 A per phase for many small PM stepper motors | Phase current, peak current, and allowable thermal load | The driver must regulate the motor phase current correctly. Excess current can cause overheating; insufficient current reduces available torque. | Confirm the rated current per phase and measure winding temperature during the worst operating cycle. |
| Number of Phases | Common configurations: 2-phase bipolar or 4-wire unipolar-compatible windings | Motor lead arrangement and driver topology | Choose a driver that matches the winding configuration. A four-wire motor is generally used with a bipolar driver. | Identify coil pairs with a resistance measurement and follow the motor wiring specification. |
| Duty Cycle | Intermittent, cyclic, or continuous operation | Run time, rest time, cycle frequency, and energized holding duration | Continuous current and holding torque can increase motor temperature, especially when the shaft is stationary but energized. | Verify temperature rise at the highest duty cycle and in the actual mounting enclosure. |
| Rotor Inertia | Typically low for compact PM motors; exact value is motor-specific | Load inertia, rotor inertia, and inertia ratio | Low inertia supports quick response, but a large external inertia can require lower acceleration or a larger motor. | Calculate reflected inertia through gears, pulleys, or lead screws and test the acceleration profile. |
| Holding Torque | Often approximately 0.01–0.15 N·m in compact PM designs | Torque required while stationary and energized | Holding torque is measured at zero speed and should not be treated as available torque at operating speed. | Check whether the load can back-drive the mechanism when power is removed. |
| Backlash and Mechanical Transmission | Depends on gearbox, belt, lead screw, coupling, and bearing system | Permitted backlash, transmission ratio, and output load | A motor cannot compensate for mechanical backlash in open-loop operation. Use suitable gearing or a feedback system when positioning accuracy is critical. | Measure output-shaft backlash and lost motion in both rotation directions. |
| Physical Size | Common compact frame dimensions: approximately 20–42 mm square | Maximum width, height, length, shaft diameter, and mounting pattern | Confirm that the motor, connector, wiring, and driver fit within the available space without restricting cooling. | Allow clearance for shaft coupling, mounting screws, cable bending, and service access. |
| Environmental Conditions | Indoor clean environments are typical; temperature and humidity limits are motor-specific | Ambient temperature, humidity, dust, vibration, shock, and installation altitude | Use appropriate sealing, protection, materials, and derating when the motor operates in dust, moisture, vibration, or elevated temperature. | Compare the application conditions with the motor’s specified operating and storage limits. |
| Noise and Resonance | Noise and vibration depend on step angle, load, speed, current waveform, and mounting | Acceptable audible noise, vibration, and resonance range | Use suitable acceleration profiles, current control, damping, or mechanical isolation when the application is sensitive to vibration. | Sweep the operating speed range and check for resonance, audible noise, and position loss. |
| Control and Feedback | Open-loop control is common; encoder feedback is optional | Controller pulse rate, direction signal, homing method, and fault detection | Open-loop operation is suitable when the load is predictable. Add feedback when missed steps cannot be tolerated. | Define maximum step frequency, pulse timing, homing accuracy, and recovery behavior after a fault. |
| Safety and Fail-Safe Behavior | Holding torque disappears or decreases when power is removed | Required behavior during power loss, overload, or controller failure | Use a brake, self-locking transmission, counterbalance, or closed-loop control when uncontrolled movement could be hazardous. | Perform power-loss and emergency-stop tests with the maximum permitted load. |